Element4 Summum C
View larger Turn the corner.
Keep the fire in view.
- Fire view
- Corner
- Model sizes
- 3
- Energy class
- A
Choose your setup
Viewing-opening dimensions, not the overall appliance or installation clearances.
Your selection is sent as an enquiry preference. The pictures retain the named model shown. Add any interior, glazing or left/right corner preference to your message; the team will confirm the complete specification and installation requirements.
View glazing and controlsPrice on request · installation quoted separately
Price on request. Contact our Macclesfield showroom to confirm the exact model, options and any display before travelling.
View larger Summum C combines the main front pane with a glazed end. It brings the fire into view from an adjacent seating area or from the approach into the room. Left and right corner versions have separate orientations, so a room sketch is useful before ordering. The 100, 140 and 190 also change the balance between the length and height of the front opening; they are not simply the same shape enlarged.
Compare the exact models
The opening
and the complete appliance.
Photographs show the named model in its manufacturer setting. Front viewing dimensions below describe the visible fire opening, not the overall appliance or the required construction space.

Element4 · Gas
Summum 100 C
Front viewing opening: 984 × 545mm
Natural gas G20: 2.8 - 11.4 kW; propane G31: 2.8 - 11.2 kW. Published efficiency: 89%, energy class A. The external front frame measures 1035.5 × 557mm. The side viewing width is 313mm. Use the full model drawing for the appliance envelope and installation space.

Element4 · Gas
Summum 140 C
Front viewing opening: 1383 × 420mm
Natural gas G20: 2.7 - 18.2 kW; propane G31: 3.7 - 18.5 kW. Published efficiency: 90%, energy class A. The external front frame measures 1429 × 427mm. The side viewing width is 296mm. Use the full model drawing for the appliance envelope and installation space.

Element4 · Gas
Summum 190 C
Front viewing opening: 1886 × 420mm
Natural gas G20: 2.7 - 18.2 kW; propane G31: 5.1 - 16.2 kW. Published efficiency: 90%, energy class A. The external front frame measures 1929 × 427mm. The side viewing width is 359mm. Use the full model drawing for the appliance envelope and installation space.
Specify the details
Glazing, controls
and the finished setting.
Include any preferences with your enquiry. The quotation should identify the exact appliance, gas type and optional equipment.
Steel interior
A dark steel interior on applicable front, corner and three-sided versions.
Black glass interior
An alternative reflective interior on applicable models. Confirm the exact specification with the quotation.
Anti-reflective glass
Available as an option in the current range. Ask for the appropriate glazing specification to be included in the quotation.
Controls and installation options
Remote control, app control and LED fire-bed lighting are listed as standard. Home automation, safety-screen and Powerfan options need checking against the exact appliance and installation.
Model-by-model figures
Dimensions and
gas performance.
Choose the row for the exact size and gas type. The front-opening measurements are kept separate from frame and body measurements.
| Fuel | Natural gas G20 or propane G31, in the correct appliance version |
|---|---|
| Fire view | Front and one end; left or right corner |
| Summum 100 C · G20 output range | 2.8 - 11.4 kW |
| Summum 100 C · G31 output range | 2.8 - 11.2 kW |
| Summum 100 C · efficiency / energy class | 89% / A |
| Summum 100 C · front viewing opening W × H | 984 × 545mm |
| Summum 100 C · external front frame W × H | 1035.5 × 557mm |
| Summum 100 C · side viewing width | 313mm |
| Summum 140 C · G20 output range | 2.7 - 18.2 kW |
| Summum 140 C · G31 output range | 3.7 - 18.5 kW |
| Summum 140 C · efficiency / energy class | 90% / A |
| Summum 140 C · front viewing opening W × H | 1383 × 420mm |
| Summum 140 C · external front frame W × H | 1429 × 427mm |
| Summum 140 C · side viewing width | 296mm |
| Summum 190 C · G20 output range | 2.7 - 18.2 kW |
| Summum 190 C · G31 output range | 5.1 - 16.2 kW |
| Summum 190 C · efficiency / energy class | 90% / A |
| Summum 190 C · front viewing opening W × H | 1886 × 420mm |
| Summum 190 C · external front frame W × H | 1929 × 427mm |
| Summum 190 C · side viewing width | 359mm |
| Flue collar in model drawings | 130 / 200mm concentric |
| Controls | Remote and app control listed as standard in the current manufacturer range |
| Burner / fire-bed lighting | Real Flame burner / LED lighting |
Figures follow the current Element4 gas pages and linked metric drawings. Output ranges differ by gas type; viewing dimensions are not installation clearances. The supplied appliance manual and an assessed flue design determine the installation.
For your home
Plan the fire
with the room.
Early measurements and photographs make the initial discussion more useful. A site assessment may still be required before the installation can be confirmed.
Choose which end should open up
Stand facing the proposed front of the fireplace and mark the side you want glazed. Include that sketch with your enquiry so the left or right version is unambiguous.
Look from both parts of the room
A corner fire can work differently from the sofa and from a doorway. Check both sightlines before committing to its height or the depth of the surrounding wall.
Plan the structure around the corner
The enclosing construction, access for servicing and flue route need planning together. Bring photographs and measurements to the Macclesfield team for a first discussion.
From Element4
Exact drawings.
The matching instructions.
Use the gas manual and metric drawing for the selected size and viewing format.
Summum 100 C · metric drawing
Exact viewing, frame and appliance measurements; not the finished enclosure size.
Summum 100 · gas installation manual
Instructions for this size, gas version, construction, servicing and approved flue arrangements.
Summum 140 C · metric drawing
Exact viewing, frame and appliance measurements; not the finished enclosure size.
Summum 140 · gas installation manual
Instructions for this size, gas version, construction, servicing and approved flue arrangements.
Summum 190 C · metric drawing
Exact viewing, frame and appliance measurements; not the finished enclosure size.
Summum 190 · gas installation manual
Instructions for this size, gas version, construction, servicing and approved flue arrangements.
Element4 · 2026 gas brochure
Current gas range, model photographs and published performance.
Explore Element4
Compare the viewing formats
Front, corner, three-sided and four-sided fires need different room layouts.
A simple first step
Ask about your Summum C · 100 / 140 / 190
Your selected size and gas preference are included below. Add a room photograph, postcode and any glazing or corner-orientation requirements.
Prefer to talk? Call 01625 402900.
Macclesfield showroom
See it in person before you decide
Photographs only go so far. Come to the Macclesfield showroom to compare finishes, sizes and flame pictures side by side and talk through your room with the team.